Pulse Output Device (POD)
Electronic Pulse Output for Positive Displacement Metering
•Glandlessdrive
•Nodynamicsealstofailorleak
•Unscaledpulseoutput
•Easilyadaptstoremotetotalizers,batchcontrollers,
computers,PLC’sandotherpulsereceivingdevices.
•Noamplierorsignalconditionerrequired
•Wettedparts316stainlesssteelorequivalent
Features & Benefits
Pulse Output Device (POD)
General Information
The Liquid Controls Pulse Output Device (POD)
converts the rotary motion of Liquid Controls
Positive Displacement Flowmeters into electronic
pulses that equal the volumetric measurements of
the meter.
The POD mounts directly to the front cover of the
meter in place of the packing gland. The motion of
the meter’s blocking rotor is magnetically coupled
through a stainless steel wall to the electronics
compartment of the POD. This eliminates the
dynamic seal of the packing gland and isolates the
electronics from the process fluid in the meter.
The electronic pulses generated by the POD
is easily adapted to a wide variety of electronic
monitoring devices and control equipment.
www.lcmeter.com
•Meetscurrentenvironmentalstandards:Weights&
Measures;NEMA4X;ClassI,Div.1&2,GroupsC&
D;DNV11ATEX01600XandIECExDNV11.0012X
•350PSI(24BAR)workingpressurerating
•Burstpressureexceeds1,750PSI(121BAR)
•½"NPTconduitportwitharemovablescrewterminal
block
Specifications
Voltage
• 9 to 30 VDC; POD5 is 5 VDC
Current supply
• 50 mA maximum
Output Signal Resolution
• 100 pulses per channel per revolution,
unscaled see table
Square Wave
• Single channel output channel A or
channel B
• Quadrature channel output channel A
and channel B
Pulse Timing
• Nominal 50% on and 50% off
Rise/Fall Time of Pulse
• <5 µs
Operating Temperature Range
• -40 to 176 °F (-40 to 80 °C)
Output
• Current sinking100 mA maximum in
“ON” state
V+ supply @ 2.2 K in “OFF” state.
• Optional Open Drain FET (Field Effect
Transistor).
• FET rating (drain to source voltage) 30
VDC maximum
Humidity Range
• 0-100%, non-condensing
Shock
• 50 Gs for 10 ms
Vibration
• 1 G at 10-150 Hz
Pulse Transmission Distance
• 5,000 feet (1,524 meters)
Electromagnetic Compatibility (EMI,
RFI, etc.)
• EU Directive 2004/108/EC (EMC)
• IEC 61000-4-2
• IEC 61000-4-3
• IEC 61000-4-5
• IEC 61000-4-6
• IEC 61000-4-17
• IEC 61000-4-29
• IEC 61000-6-3
• ISO 7637-2